Overview / Design Principle:

Northstar's HSD25 Harsh Duty Industrial Hubshaft Optical Encoder accepts up to 0.78" diameter shafts and operates reliably from -40 to 100°C.    The hard anodized finish encoder exceeds IP66/IP67 and NEMA 6 enclosure requirements.

This robust encoder is also available in stainless steel to meet NEMA 4X and 6P requirements and its sealed housing allows the encoder to be operated when regulatory washdown and high  pressure steam orcaustic chemicals are required. Utilization of an advanced Opto ASIC with innovative packaging techniques enables the encoder to operate in high shock and vibration environments.

The HSD25 heavy duty optical encoders are also available in an intrinsically-safe version certified to ATEX EEX IA IIB T4 used with the appropriate IS barrier.


Features and Benefits:

Mechanical and Environmental

  • Unbreakable code disks for 1 to 3600 PPR
  • Hubshaft mounting
  • Heavy-duty shaft seals
  • Sealed connector - no soldering

Electrical

  • Cast housing maximizes noise immunity and durability

Applications/ Industries:

The HSD25 harsh duty encoder features simple installation on motor or machine hub shafts. It is often mounted on the back of motors where encoder feedback is needed in harsh environment applications.  Available housing options make it ideal use in corrosive environments that demand heavy washdown protection.

ATEX certification is also available for intrinsically safe applications.

• Converting Machinery

• Material Handling

• Packaging Equipment

• Oil Field Exploration

• Processing Equipment

Standard Operating Characteristics
Code: Optical Incremental
Pulses per Revolution: 1-3600
Phasing Sense: A leads B for Clockwise rotation (CCW) viewing shaft rotation viewing the shaft clamp end of the encoder
Quadrature Phasing: 90° ± 15°
Symmetry: 180° ± 18°
Index: 180° ± 18°

Electrical
Input Voltage Requirement: 5-26 Volts VDC; 5DVC; 7-26VDC (ATEX)
Current Requirement: 50 mA typical plus line driver load
Output Signals: With Elec Option 0, 1, 2, 4, A & B: 5-26 V Line Driver, 40mA
With Elec Option 3: 5 V Line Driver, 40mA
With Elec Option 5: 5 V Line Driver, 100mA
With Elec Option 6: 5-15 V Line Driver, 100mA
Frequency Response: 0 - 125kHz Data & Index
Electrical Immunity: 1kV ESD, Reverse Polarity, Short Circuit
Connector: 6,7 or 10 pin style MS3 connectors available;  18" cable exit with seal

Mechanical
Shaft Speed: 3,600 RPM; Max up to 6000 RPM
Mounting Configuration: Flexible mount with anti-rotation arm
Housing Material: Hard anodized aluminum, stainless steel or nickel plated versions available
Available Shaft Sizes: 3/8", 1/2", 5/8 3/4" or 10mm  thru-shaft style available. See ordering table for sizes.
Allowable Shaft End-Play: ± 0.050”
Allowable Shaft Runout: 0.025” TIR (Subject to RPM Limitation)

Environmental
Operating Temperature Range: -40°C to +100°C; -40°C to +80°C (ATEX) 
Storage Temperature Range: -40°C to +100°C
Humidity: to 98% RH (non-condensing)
Shock: 50 Gs for 11 ms
Vibration: 20 Gs @ 5-2000 Hz spectrum